Medical


   MQ1D-5120V(120W) ...... 
Dimension:190.00x83.80x40.00  (mm) / 7.48x3.30x1.57  (inch)
Input:VOLTAGE: 90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC
70A MAX. FOR 230 VAC
   MP1S-5220V(220W) ...... 
Dimension:190.00x81.50x40.30  (mm) / 7.48x3.21x1.59  (inch)
Input:INPUT CHARACTERISTICS:VOLTAGE:90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:3.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 
95% AT 115/230VAC, FULL LOAD
   MP1S-5300V(300W) ...... 
Dimension:190.00x81.50x40.30  (mm) / 7.48x3.21x1.59  (inch)
Input:INPUT CHARACTERISTICS:VOLTAGE:90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 
95% AT 115/230VAC, FULL LOAD
   MP1S-6300V(300W) ...... 
Dimension:190.00x81.50x40.30  (mm) / 7.48x3.21x1.59  (inch)
Input:INPUT CHARACTERISTICS:VOLTAGE:90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 
95% AT 115/230VAC, FULL LOAD
   MHG2-6300P(300W) ...... 
Dimension:140.00x150.00x86.00  (mm) / 5.51x5.91x3.39  (inch)
Input:VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 5A FOR 115VAC; 2.5A FOR 230VAC
INRUSH CURRENT: 65A MAX. FOR 115 VAC; 125A MAX. FOR 230 VAC
   MHG2-6350P(350W) ...... 
Dimension:140.00x150.00x86.00  (mm) / 5.51x5.91x3.39  (inch)
Input:VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 5A FOR 115VAC; 2.5A FOR 230VAC
INRUSH CURRENT: 65A MAX. FOR 115 VAC; 125A MAX. FOR 230 VAC
   MV1E-5350V(350W) ...... 
Dimension:260.00x100.00x40.50  (mm) / 10.24x3.94x1.59  (inch)
Input:VOLTAGE: 90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:6A (RMS) FOR 115 VAC / 
3A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC / 
30A MAX. FOR 230 VAC
   MHG2-6400P(400W) ...... 
Dimension:140.00x150.00x86.00  (mm) / 5.51x5.91x3.39  (inch)
Input:VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 7A FOR 115VAC; 3.5A FOR 230VAC
INRUSH CURRENT: 65A MAX. FOR 115 VAC; 125A MAX. FOR 230 VAC
   MHU2-5400V(400W) ...... 
Dimension:150.00x140.00x86.00  (mm) / 5.91x5.51x3.39  (inch)
Input:VOLTAGE:100∼240VAC FULL RANGE(WITH ±10% TOLERANCE)
FREQUENCY:47∼63HZ
INPUT CURRENT:6A (RMS) FOR 115 VAC
3A (RMS) FOR 230 VAC
INRUSH CURRENT:20A MAX. FOR 115 VAC
40A MAX. FOR 230 VAC
   MP1S-6400V(400W) ...... 
Dimension:250.00x81.50x40.30  (mm) / 9.84x3.21x1.59  (inch)
Input:INPUT CHARACTERISTICS:VOLTAGE:90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 
95% AT 115/230VAC, FULL LOAD
   MP2M-5435V(435W) ...... 
Dimension:270.00x100.00x70.00  (mm) / 10.63x3.94x2.76  (inch)
Input:VOLTAGE: 90~264 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:3A(RMS)FOR 230VAC
               7A(RMS)FOR 115VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE 
                30A MAX. FOR 230 VAC PER MODULE
PFC CAN REACH THE TARGET OF 95% @115/230VAC, FULL LOAD
   MPSM-5500V(550W) ...... 
Dimension:160.00x150.00x86.00  (mm) / 6.30x5.90x3.39  (inch)
Input:VOLTAGE:  90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 8A FOR 115VAC; 4A FOR 230VAC
INRUSH CURRENT: 20A MAX. FOR 115 VAC; 40A MAX. FOR 230 VAC
PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
THE POWER SUPPLY SHALL INCORPORATE UNIVERSAL POWER 
INPUT WITH ACTIVE POWER FACTOR CORRECTION, WHICH 
SHALL REDUCE LINE HARMONICS IN ACCORDANCE WITH 
THE EN61000-3-2 STANDARDS.