ZIPPY - P_product

V2_logo.gif

chinese english contact sitemap
Keywords Search:
New Products
Products
Open Frame
Medical
Easy Swap
1U Single
Mini 1U Single
2U Single
3U Single
PS2
PS2+
PS2*2 Redundant
Cloud Power
1U Redundant
2U Redundant
Mini Redundant
N+1 Redundant
Micro Redundant
Redundant module
Search:

New Products


   M1X2-5550V0V(550W) ...... 
Dimension:240.00x101.00x84.00  (mm) / 9.45x3.98x3.31  (inch)
Input :VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 4.0 A (RMS) FOR 230 VAC
8.0A (RMS) FOR 115 VAC
INRUSH CURRENT: 30A MAX. FOR 115 VAC PER MODULE
60A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC CAN REACH THE 
TARGET OF 95% AT 230V, FULL LOAD
   M1X2-5700V0V(700W) ...... 
Dimension:240.00x101.00x84.00  (mm) / 9.45x3.98x3.31  (inch)
Input :VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
INPUT CURRENT: 5.5A (RMS) FOR 230 VAC
11A (RMS) FOR 115 VAC
INRUSH CURRENT: 30A MAX. FOR 115 VAC PER MODULE
60A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC CAN REACH THE 
TARGET OF 95% AT 230V, FULL LOAD
   M1W1-5E00V3H(1400W) ...... 
Dimension:320.00x98.40x40.00  (mm) / 12.60x3.87x1.57  (inch)
Input :VOLTAGE: 115 ~ 240 VAC FULL RANGE (With ±10% tolerance)
FREQUENCY: 47 ~ 63 Hz
INPUT CURRENT: 15/10 AMPS MAXIMUM AT ANY LOW/HIGH 
RANGE INPUT VOLTAGE
INRUSH CURRENT: 15/30 AMPS @115/230 VAC. 
(HIGH FREQUENCY PEAK AMPLITUDES LASTING LESS 
THAN 200US(AT 25 DEGREES AMBIENT COLD START 
FOR EACH POWER UNIT)
   MTW4-5F50V3H(1550W) ...... 
Dimension:340.00x422.00x43.00  (mm) / 13.39x16.61x3.27  (inch)
Input :VOLTAGE: 90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT (PER POWER MODULE):24 / 11 AMPSMAXIMUM AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT (PER POWER MODULE):40/60A MAX. FOR 
115/230VAC (25℃)
   HG2-5400E(400W) ...... 
Dimension:140.00x150.00x86.00  (mm) / 5.51x5.91x3.39  (inch)
Input :VOLTAGE:  90 ~ 240 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 5.5/3A FOR 115/230VAC
INRUSH CURRENT: 35/80 MAX. FOR 115/230VAC
   M1P1-5500V4H(500W) ...... 
Dimension:250.00x84.00x41.80  (mm) / 9.84x3.31x1.65  (inch)
Input :VOLTAGE: 90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:4A(RMS)FOR 230VAC
8A(RMS)FOR 115VAC
INRUSH CURRENT:40A MAX. FOR 115 VAC PER MODULE 
60A MAX. FOR 230 VAC PER MODULE
   HG2-5600E(600W) ...... 
Dimension:140.00x150.00x86.00  (mm) / 5.51x5.91x3.39  (inch)
Input :VOLTAGE:  90 ~ 240 VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT: 8.5/4.5A FOR 115/230VAC
INRUSH CURRENT: 35/80 MAX. FOR 115/230VAC
   BMTW4-5G20V3H(1620W) ...... 
Dimension:340.00x422.00x43.00  (mm) / 13.40x16.60x1.70  (inch)
Input :VOLTAGE: 19 ~ 36VDC, NOMAL 24VDC
STEADY-STATE CURRENT: 135/63AMPS AT ANY LOW/HIGH RANGE INPUT VOLTAGE
INRUSH CURRENT: 50AMPS @ 24VDC
   R1S2-5480V4V(480W) ...... 
Dimension:207.00x85.00x84.00  (mm) / 8.15x3.35x3.31  (inch)
Input :VOLTAGE: 200∼240VAC FULL RANGE(WITH +/-10 TOLERANCE)
FREQUENCY: 47∼63HZ
INPUT CURRENT:4A (RMS) FOR 115 VAC
 2.5A (RMS) FOR 230 VAC
INRUSH CURRENT:30A MAX. FOR 230 VAC PER MODULE
   MTW4-5H80V3V(1780W) ...... 
Dimension:300.00x101.20x166.00  (mm) / 11.81x3.98x6.54  (inch)
Input :VOLTAGE:  90V ~ 264VAC (WITH ± 10% TOLERANCE)
FREQUENCY: 47Hz ~ 63Hz 
INPUT CURRENT: INPUT CURRENT:27/12A MAX AT ANY 
LOW/HIGH INPUT VOLTAGE
INRUSH CURRENT: 40A MAX. FOR 115 VAC PER MODULE; 
60A MAX. FOR 230 VAC PER MODULE
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 
95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 
61000-3-2
   MRT-5320G0V(320W) ...... 
Dimension:185.00x150.00x86.00  (mm) / 7.28x5.91x3.39  (inch)
Input :VOLTAGE:  90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 Hz
INPUT CURRENT: 5/3A @ 115 / 230 VAC 
INRUSH CURRENT: 25/50 AMPS @115/230 VAC 
(AT 25 DEGREES AMBIENT COLD START FOR EACH POWER UNIT)
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 
95% @ 115V, FULL LOAD, FOLLOWING THE STANDARD OF IEC 
1000-3-2
   R1S2-5120V0V(120W) ...... 
Dimension:150.00x85.00x84.00  (mm) / 5.91x3.35x3.31  (inch)
Input :VOLTAGE: 90∼264VAC FULL RANGE
FREQUENCY: 47∼63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
 1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
 70A MAX. FOR 230 VAC PER MODULE